No. Name
User
Setting
d4-03 Frequency Reference Bias Step (Up/Down 2)
d4-04 Frequency Reference Accel/Decel (Up/Down 2)
d4-05
Frequency Reference Bias Operation Mode Selection (Up/
Down 2)
d4-06 Frequency Reference Bias (Up/Down 2)
d4-07
Analog Frequency Reference Fluctuation Limit (Up/Down
2)
d4-08 Frequency Reference Bias Upper Limit (Up/Down 2)
d4-09 Frequency Reference Bias Lower Limit (Up/Down 2)
d7-01 Offset Frequency 1
d7-02 Offset Frequency 2
d7-03 Offset Frequency 3
E1-01 Input Voltage Setting
E1-03 V/f Pattern Selection
E1-04 Max Output Frequency (FMAX)
E1-05 Max Voltage (VMAX)
E1-06 Base Frequency (FA)
E1-07 Mid Output Frequency (FB)
E1-08 Mid Output Frequency Voltage (VC)
E1-09 Minimum Output Freq. (FMIN)
E1-10 Minimum Output Freq. Voltage (VMIN)
E1-11 Mid Output Frequency 2
E1-12 Mid Output Frequency Voltage 2
E1-13 Base Voltage (VBASE)
E2-01 Motor Rated Current
E2-02 Motor Rated Slip
E2-03 Motor No-Load Current
E2-04 Number of Motor Poles
E2-05 Motor Line-to-Line Resistance
E2-06 Motor Leakage Inductance
E2-07 Motor Iron-Core Saturation Coefficient 1
E2-08 Motor Iron-Core Saturation Coefficient 2
E2-09 Motor Mechanical Loss
E2-10 Motor Iron Loss for Torque Compensation
E2-11 Motor Rated Output
E2-12 Motor Iron-Core Saturation Coefficient 3
E3-01 Motor 2 Control Method Selection
E3-04 Motor 2 Max Output Frequency
E3-05 Motor 2 Max Voltage (VMAX)
E3-06 Motor 2 Base Frequency (FA)
E3-07 Motor 2 Mid Output Frequency (FB)
E3-08 Motor 2 Mid Output Frequency Voltage (VC)
E3-09 Motor 2 Minimum Output Freq.(FMIN)
E3-10 Motor 2 Minimum Output Freq. Voltage (VMIN)
E3-11 Motor 2 Mid Output Freq. 2
E3-12 Motor 2 Mid Output Freq. Voltage 2
E3-13 Motor 2 Base Voltage (VBASE)
E4-01 Motor 2 Rated Current
E4-02 Motor 2 Rated Slip
E4-03 Motor 2 Rated No-Load Current
E4-04 Motor 2 Motor Poles
E4-05 Motor 2 Line-to-Line Resistance
E4-06 Motor 2 Leakage Inductance
E4-07 Motor 2 Motor Iron-Core Saturation Coefficient 1
E4-08 Motor 2 Motor Iron-Core Saturation Coefficient 2
E4-09 Motor 2 Mechanical Loss
E4-10 Motor 2 Iron Loss
E4-11 Motor 2 Rated Capacity
E4-12 Motor 2 Iron-Core Saturation Coefficient 3
E4-14 Motor 2 Slip Compensation Gain
E4-15 Torque Compensation Gain - Motor 2
E5-01 Motor Code Selection (PM motor)
E5-02 Motor Rated Capacity (PM motor)
E5-03 Motor Rated Current (PM motor)
E5-04 Motor Poles (PM motor)
E5-05 Motor Armature Resistance (PM motor)
E5-06 Motor d Axis Inductance (PM motor)
E5-07 Motor q Axis Inductance (PM motor)
E5-09 Motor Induction Voltage Constant 1 (PM motor)
E5-24 Motor Induction Voltage Parameter 2 (PM motor)
F1-02 Operation Selection at PG Open Circuit (PGO)
F1-03 Operation Selection at Overspeed (OS) (for Simple PG V/f)
No. Name
User
Setting
F1-04
Operation Selection at Deviation (for Simple PG V/f
Control)
F1-08 Overspeed Detection Level(for Simple PG V/f Control)
F1-09
Overspeed Detection Delay Time(for Simple PG V/f
Control)
F1-10
Excessive Speed Deviation Detection Level (for Simple PG
V/f Control)
F1-11
Excessive Speed Deviation Detection Delay Time (for
Simple PG V/f Control)
F1-14
PG Open-Circuit Detection Time(for Simple PG V/f
Control)
F6-01 to F6-41 Range reserved
F7-01 to F7-21 Range reserved
H1-01
Multi-Function Digital Input Terminal S1 Function
Selection
H1-02
Multi-Function Digital Input Terminal S2 Function
Selection
H1-03
Multi-Function Digital Input Terminal S3 Function
Selection
H1-04
Multi-Function Digital Input Terminal S4 Function
Selection
H1-05
Multi-Function Digital Input Terminal S5 Function
Selection
H1-06
Multi-Function Digital Input Terminal S6 Function
Selection
H1-07
Multi-Function Digital Input Terminal S7 Function
Selection
H2-01 Terminal MA, MB and MC Function Selection (relay)
H2-02 Terminal P1 Function Selection (open-collector)
H2-03 Terminal P2 Function Selection (open-collector)
H2-06 Watt Hour Output Unit Selection
H3-01 Terminal A1 Signal Level Selection
H3-02 Terminal A1 Function Selection
H3-03 Terminal A1 Gain Setting
H3-04 Terminal A1 Bias Setting
H3-09 Terminal A2 Signal Level Selection
H3-10 Terminal A2 Function Selection
H3-11 Terminal A2 Gain Setting
H3-12 Frequency Reference (Current) Terminal A2 Input Bias
H3-13 Analog Input Filter Time Constant
H4-01 Multi-Function Analog 1 (Terminal AM Monitor Selection)
H4-02 Multi-Function Analog 1 (Terminal AM Output Gain)
H4-03 Multi-Function Analog 1 (Terminal AM Output Bias)
H5-01 Drive Node Address
H5-02 Communication Speed Selection
H5-03 Communication Parity Selection
H5-04 Stopping Method After Communication Error
H5-05 Communication Fault Detection Selection
H5-06 Drive Transmit Wait Time
H5-07 RTS Control Selection
H5-09 CE Detection Time
H5-10 Unit Selection for MEMOBUS/Modbus Register 0025H
H5-11 Communications ENTER Function Selection
H5-12 Run Command Method Selection
H6-01 (Terminal RP) Pulse Train Input Function Selection
H6-02 Pulse Train Input Scaling
H6-03 Pulse Train Input Gain
H6-04 Pulse Train Input Bias
H6-05 Pulse Train Input Filter Time
H6-06 (Terminal MP) Pulse Train Monitor Selection
H6-07 Pulse Train Monitor Scaling
L1-01 Motor Overload Protection Selection
L1-02 Motor Overload Protection Time
L1-03 Motor Overheat Alarm Operation Selection (PTC input)
L1-04 Motor Overheat Fault Operation Selection (PTC input)
L1-05 Motor Temperature Input Filter Time (PTC input)
L1-13 Continuous Electrothermal Operation Selection
L2-01 Momentary Power Loss Operation Selection
L2-02 Momentary Power Loss Ride-Thru Time
L2-03 Momentary Power Loss Minimum Baseblock Time
L2-04 Momentary Power Loss Voltage Recovery Ramp Time
L2-05 Undervoltage Detection Level (UV)
L2-06 KEB Deceleration Time
L2-07 Momentary Power Loss Ride-Thru Time
L2-08 Minimum Frequency Gain at KEB Start
D.5 User Setting Table
358