Introduction Fan Module Alarms
Software Reference for SwitchBlade x3100 Series Switches (Setting Up the Switch)
1-198
CLEAR ALARMS CARD MCASTGROUPLIMIT
Syntax
CLEAR ALARMS CARD={ slot-list | ALL } MCASTGROUPLIMIT
Description Clears the specified alarm condition on the given card. Currently only the MCAST-
GROUPLIMIT alarm can be cleared with this command.
Options The following table gives the range of values for each option that can be specified with
this command and a default value (if applicable).
Example
CLEAR ALARMS CARD=ALL MCASTGROUPLIMIT
Option Description Default Value
CARD Specified slots or ALL
The MCASTGROUPLIMIT parameter signifies the alarm
condition associated with exceeding the threshold on
the number of multicast groups allowed to be active on
a card. When the threshold is exceeded, this alarm is
raised against the card, and is only cleared by executing
this command. The number of multicast groups for a
card is configured using the SET IGMPSNOOPING
command with the GRPLIMIT parameter, and is dis-
played using the SHOW IGMPSNOOPING command
with the GRPLIMIT parameter.