GE Interfaces Example Output
Software Reference for SwitchBlade x3100 Series Switches (Interface Management)
2-14
SET INTERFACE GE
Syntax
SET INTERFACE={ type: | type:id-range | id-range | ifname-list |
ALL }
GE
[ AUTONEGOTIATION={ ON | OFF } ]
[ SPEED={ AUTONEGOTIATE | 10 | 100 | 1000 } ]
[ DUPLEX={ AUTONEGOTIATE | FULL | HALF } ]
[ FLOWCONTROL={ AUTONEGOTIATE | ON | OFF } ]
[ DIRECTION={ NETWORK | CUSTOMER } ]
[ FORCE ]
Description Modifies the provisioning attributes for the specified interface or list of interfaces. One
or more individual attributes or a profile name are specified. Some individual attributes
can be modified while the interface is in-service. These in-service modified attributes are
downloaded to the hardware dynamically. For other attributes, the interface must be dis-
abled (See DISABLE INTERFACE) If a profile is used to modify all attributes, the interface
must be disabled first, and all attributes are downloaded again when the interface is
enabled.
Options The following table gives the range of values for each option that can be specified with
this command and a default value (if applicable).
Option Description Default Value
INTERFACE The GE interfaces that are being modified.
AUTONE-
GOTIATION
Specifies whether automatic negotiation of transmission
parameters for GE ports is allowed. The user may set
this parameter only when the interface is disabled.
Whether ON or OFF, the port speed is fixed at
1000BASE-X with full duplex.
If ON, the port has increased flexibility to communicate
with the remote peer. The port has the ability to adver-
tise flow control and to provide single direction fault
coverage. The port will drive the link state up and down
based on the ability to communicate with the remote
peer, triggering on both transmit and receive failures
(LOS).
If OFF, the port state is driven by receive failure (LOS).
Flow control is still provided as long as the FLOW-
CONTROL parameter is ON.
ON
SPEED The speed of the interface (10, 100, 1000, AUTO).
Note that some combinations are with other parame-
ters are incompatible. (Refer to Section 2.3.)
AUTO

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis SwitchBlade x3100 Series and is the answer not in the manual?

Allied Telesis SwitchBlade x3100 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelSwitchBlade x3100 Series
CategorySwitch
LanguageEnglish

Related product manuals