Introduction EPSR and (R)STP Interaction
Software Reference for SwitchBlade x3100 Series Switches (Layer Two Switching)
4-156
DELETE TRACE EPSR MESSAGETYPE
Description Delete the events which match the given filters.
Syntax
DELETE TRACE EPSR [ ={ epsrdomain-list | ALL } ] [ MESSAGETYPE={
HEALTH | RINGUPFLUSH | RINGDOWNFLUSH | LINKDOWN | LINKFORWARD-
REQUEST | PERMISSIONLINKFORWARD | QUERYLINKSTATUS | ALL } ] [
INTERFACE={ type:id-range | id-range | ifname-list | ALL }
Options The following table gives the range of values for each option that can be specified with
this command and a Default Value (if applicable).
Example DELETE TRACE EPSR GA MESSAGETYPE HEALTH
Option Description Default Value
EPSR The name(s) that has been given to the EPSR
domain(s)
NA
MESSAGETYPE The EPSR message types If not input, will
default to wild-
card (ALL)
INTERFACE The interfaces where the TRACE will occur If not input, will
default to wild-
card (ALL)