Configurable Alarm Severity (Interface Alarm) Introduction
8-11
Software Reference for SwitchBlade x3100 Series Switches (Alarms and Troubleshooting)
SHOW ALARMS
Syntax
SHOW ALARMS [ { ALL | CARD={ slot-list | ACTCFC | INACTCFC | ALL }
| INTERFACE={ type:id-range | id-range | ifname-list | ALL } } ] [
SEVERITY={ CRITICAL | MAJOR | MINOR | INFO | ALL } ] [ FULL ]
Description Displays alarm conditions on system components. The display is filtered according to the
given parameters and shown in a tabular output, with one alarm per row. There are 4 col-
umns of output for each alarm consisting of:
The component the alarm is against
A description of the fault or condition
The severity of the alarm
The time and date the alarm occurred.
Options The following table gives the range of values for each option that can be specified with
this command and a default value (if applicable).
Example SHOW ALARMS ALL
E135 - manager SEC>> SHOW ALARMs CARD=1 FULL
Option Description Default Value
ALARMS The type of alarms to display
ALL
CARD
ACTFCF
INACTCFC
ALL
ALL
INTERFACE The interfaces that will have their alarms displayed. Info
SEVERITY The severity of the alarm
CRITICAL
MAJOR
MINOR
INFO
ALL - All severities
ALL
FULL Makes SHOW ALARMS show all alarms regardless of
whether or not they are masked

Table of Contents