Approved Parts Recommendation
BD Alaris
TM
System with Guardrails
TM
Suite MX User Manual 5
Approved Parts Recommendation
CareFusion recommends the use of CareFusion manufactured parts in the operation and maintenance of
your CareFusion equipment. Customer's use of repair or service parts, add-ons, or disposables that are not
approved by CareFusion is at Customer's own risk and may void the product warranty provided by
CareFusion. Any 510(k) clearance from the Food and Drug Administration (FDA) or regulatory approval
secured by CareFusion to market Alaris pumps was based on use of only CareFusion manufactured parts
and equipment. If non-CareFusion parts, add-ons or disposables are used for the maintenance, repair or
operation of your CareFusion equipment, those parts were not validated by CareFusion for safety and
efficacy with our BD Alaris and Alaris products, nor were they included in the review and approval/
clearance of the products.
If it becomes necessary to replace the following cables or accessories
, use only approved parts that are
listed in the Technical Service Manual. Use of other parts may affect electromagnetic compliance of the
Alaris System.
PCU Power Cord
PCU Serial Cable
PCA Dose Request Cord
Handheld Barcode Scanner
Installation
Instruments are tested and calibrated before they are packaged for shipment. To ensure proper operation
after shipment, it is recommended that an incoming inspection be performed before placing the instrument
in use.
Prior to placing the system in use:
1. Perform the check-in procedure using system maintenance software (see BD Alaris
TM
System
Maintenance User Manual, Chapter 3 Preventive Maintenance).
2. Load the hospital-defined best-practice data set using one of the following methods:
If using systems manager, transfe
r the data set wirel
essly to the PCU (see BD Alaris™ Systems
Manager User Manual).
If not using systems manager, use the system maintenance
or the Guardrails editor transfer tool to
transfer the data set to the PCU (see BD Alaris
TM
System Maintenance User Manual or BD
Alaris
TM
Guardrails
TM
Editor User Manual).
3. Power cycle the PCU.
4. Press
Yes on the New Patient message to activate the data set and select the desired profile (see
Selecting New Patient and Profile Options on pa
ge 23).
NOTE:
To enable the profiles feature, a hospital-defined best-practice data set must be uploaded to the PCU.
5. Clean PCUs and all modules before placing the instruments in clinical use. Follow the procedure in
Cleaning on page 346.