Troubleshooting and Maintenance
Troubleshooting and maintenance should be performed only by qualified personnel, using the applicable
technical service manual and system maintenance software. Do not perform troubleshooting, service, or
maintenance while the system is in use with a patient.
The service manuals and system maintenance are available from CareFus
ion. The service manuals include
routine service schedules, interconnect diagrams, component parts lists and descriptions, test procedures,
and other technical information to assist qualified service personnel in repair and maintenance of the
instrument’s repairable components. System maintenance is used to perform a new instrument check-in,
preventive maintenance tests, calibration checks, calibration, and other maintenance functions.
Artifacts: It is normal for an infusion device to produce nonhazardous currents wh
en infusing electrolytes.
These currents vary proportional to the infusion device flowrate. When an ECG monitoring system is not
functioni
ng under optimal conditions, these currents might appear as artifacts, simulating actual ECG
readings.
To determine if ECG abnormalities are caused by patient condition or the ECG equipment, place
the infu
sion device on hold. If the ECG readings become normal, the ECG equipment requires attention.
Proper setup of the ECG equipment should eliminate these
artifacts. Refer to the appropriate ECG
monitoring
system documentation for instructions on setup and maintenance.
BD Alaris
TM
Systems Manager Connections
When a systems manager connection is made, the wireless network indicator on the PCU illuminates. If
connection to the systems manager is interrupted, the indicator light is extinguished. Some of the causes
for a communications failure include:
Systems manager is not accessible in network, server se
rvices are not running, or server has been shut
down.
Wireless connection to access point is down due to wireless network changes
.
Local interference.
PCU has been moved outside the wireless
coverage are
a.
Wireless network card has been damaged.
If an interruption to the systems manage
r connection continues, contact the facility's information
technology department.
BD Alaris PCU model 8015
Alaris PCU model 8015
BD Alaris pump module model 8100
Alaris pump module model 8100
BD Alaris™ PC Unit Model 8015, Alaris™ PC Unit Model 8015, BD
Alaris™ Pump Module Model 8100, and Alaris™ Pump Module
Model 8100 Technical Service Manual
Alaris syringe module model 8110
Alaris PCA module model 8120
Technical Service Manual Alaris Syringe Module, 8110 Series
Alaris PCA Module, 8120 Series
Alaris SpO
2
module models 8210 and 8220
Technical Service Manual Alaris SpO
2
Modules
Alaris EtCO
2
module model 8300
Technical Service Manual Alaris EtCO
2
Module, 8300 Series
Alaris auto-ID module model 8600
Technical Service Manual Alaris Auto-ID Module, Model 8600

Table of Contents

Other manuals for BD Alaris

Related product manuals