Bit 4
Stop axle with ramp 0x6084
Start electronic gear with reference value
master speed with ramp 0x6083
Direct Synchronisation enabled.
Direct Synchronisation disabled.
Bit 8
Execute instruction of bit 4 “Start Gear-
ing”
Stop axle with ramp of actual motion
block, inverter remains in state “operation
Bit 9
Phasing disabled / aborted
Start Phasing with profile defined by Bits
12 & 13
Phasing select 0…1
Bit 12…13
Phasing Profile = motion block select + 1:
Bit 8
Phasing in progress or none started yet.
gear
Bit 10
0
Electronic gear not coupled
1
Electronic gear is coupled
Bit 13
04/13 CM-CAN ACU 217