Control word
Name
Value
Description
Start Gearing
Bit 4
0
Stop axle with ramp 0x6084
1
Start electronic gear with reference value
master speed with ramp 0x6083
Direct Sync
Bit 6
0
Direct Synchronisation enabled.
1
Direct Synchronisation disabled.
Halt
Bit 8
0
Execute instruction of bit 4 “Start Gear-
ing
1
Stop axle with ramp of actual motion
block, inverter remains in state “operation
enabled”
Start Phasing
Bit 9
0
Phasing disabled / aborted
1
Start Phasing with profile defined by Bits
12 & 13
Phasing select 0…1
Bit 12…13
n
Phasing Profile= n + 1
Phasing select:
Control word
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Ph. Sel.
Pha
Halt
DS
SG
1
0
Phasing Profile = motion block select + 1:
Phasing select
Phasing Profile
Bit 13
Bit 12
0
0
1
1
1
2
0
0
3
1
1
4
Status word
Name
Value
Description
Phasing Done
Bit 8
0
Phasing in progress or none started yet.
1
Phasing finished.
Target reached / In
gear
Bit 10
0
Halt = 0:
Electronic gear not coupled
Halt = 1:
axle decelerates
1
Halt = 0:
Electronic gear is coupled
Halt = 1:
axle has velocity 0
Following error
Bit 13
0
No following error
1
Following error
04/13 CM-CAN ACU 217

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BONFIGLIOLI Vectron Active Cube and is the answer not in the manual?

BONFIGLIOLI Vectron Active Cube Specifications

General IconGeneral
BrandBONFIGLIOLI
ModelVectron Active Cube
CategoryDC Drives
LanguageEnglish

Related product manuals