3.1 Supported Configurations
ACTIVE CUBE inverters support different types of control and reference values:
• Standard (without Positioning functions)
• Positioning via contacts (or remote contacts)
• Positioning via Motion Control Interface (MCI) via field bus
Motion control configurations are set when parameter
configuration 30 = x40 (in example 240). To
use the full functionality of the Motion Control Interface Parameter
Local/Remote 412 = “1-Control
via State machine” must be set.
The inverter's behavior with respect to
control word | status word
and
modes of operation
/
modes of
operation display
is different in the two different types of configuration.
Standard:
Necessary settings: C
onfiguration 30 ≠ x40.
Local/Remote 412 = (Remote) contacts
The control (Start, Stop, Frequency change over, etc.) is carried out typically via:
o Digital contacts
o Remote contacts via Field bus
Reference values result from the select configuration. Typical are:
o Reference speed / Reference frequency:
Analogue input
Fixed values from parameters
0x6042 target velocity
o Percentage reference value for technology controller or Torque control
Analogue input
Fixed values from parameters
Please refer to chapter 14.3 “Non motion control configurations“ for the control without Positioning
functionality.
Positioning via contacts (or remote contacts):
Necessary settings: C
onfiguration 30 = x40.
Local/Remote 412 = (Remote) contacts
The control (Start, Stop, Target position change over, etc.) is carried out typically via:
o Digital contacts
o Remote contacts via Field bus
Reference values result from the selected configuration. Typical are:
o Reference speed / Reference frequency
o Reference target position
Please refer also to the application manual “Positioning”.
MCI (Motion Control Interface – Positioning via Field bus):
Necessary settings: C
onfiguration 30 = x40.
Local/Remote 412 = 1 - Statemachine
The control (Start, Stop, mode change over, etc.) is carried out via 0x6040
Control word
.
Reference values result from the selected 0x6060
Modes of Operation
.
Typical are:
o Reference speed via 0x6042 target velocity
o Target position 0x607A target position.
The usage of the Motion Control Interface is described in this manual in chapter 14.4 “Motion control
configurations”.