Release all HDD modules and pull them out a few centimeters, see
"Removing 3.5-inch HDD modules" on page
153.
CAUTION
The HDD modules need not to be removed.
If you want to remove them nevertheless, check if all HDD
modules are uniquely identified so that you can reinsert them
into their original bays.
Release all dummy modules and pull them out a few centimeters, see
"Removing a 3.5-inch HDD dummy module" on page
151.
Removing the defective 12x 3.5-inch HDD backplane
If applicable, remove the SAS expander board holder, see "Removing the
SAS expander board holder" on page 208.
Remove the internal RAID riser module, see "Removing an internal RAID
riser module" on page 303.
Disconnect all cables from the HDD backplane.
Figure 70: Removing the 12x 3.5-inch HDD backplane
Release the nine screws (see circles).
T
ake out the HDD backplane at a slight angle.
Hard disk drive (HDD) / solid state disk (SSD)