As soon as the startup screen appears, press the [F2]
function key to enter
the BIOS setup menu.
Select the Advanced menu.
Select the Trusted Computing submenu.
Set the TPM Support and TPM State settings to Disabled.
Save your changes and exit the BIOS.
For information on how to access the BIOS and modify settings, see the
corresponding BIOS Setup Utility reference manual.
"Suspending BitLocker functionality" on page 107.
"Shutting down the server" on page 49.
"Disconnecting the power cord" on page 50.
"Getting access to the component" on page 51.
"Removing the system air duct" on page 67.
"Removing the PCI air duct" on page 88.
If applicable, remove the riser module, see "Removing the riser module" on
page 86.
"Removing the crossbar" on page 90.
Remove the fan bridge, see "Handling the fan bridge" on page 92.
Removing the TPM
Remove the system board, see "Removing the defective system board" on
page 516.
Lay the system board on a soft, antistatic surface with its component side
facing down.
System board and components
482 Upgrade and Maintenance Manual TX2550 M5