448 Keysight N9915-90020 User’s Guide
5G Rapid Prototype Phased Array Antenna – Option 360
How to Set Up Phased Array Antenna Settings
— Array Antenna: Center frequency, Azimuth Ref, and Elevation
Ref
— Polar Display: Ref
See also
“How to Set Up Phased Array Antenna Settings” on
page 433.
d. Optional: Measure > Data Logging:
— Record Settings (Outdoor Mapping only) then choose
— Measure Interval OFF ON
— Interval Type Time Distance
— Time Interval if applicable (only active when
Interval Type = Time) or
— Distance Interval if applicable (only active when
Interval Type = Distance)
— Auto Save OFF ON
—
Back to return to previous menu
e. Record Save/Recall (Save Log File, Recall or
f.
Record or
g.
Play if you have a previously stored data scan
See also
“How to Set Up Phased Array Antenna Settings” on
page 433
and “Step 6: Enable Data Logging and Playback the
Results” on page 449.
Learn more, refer to
Chapter 16 Mapping and “Setting up Data
Logging” on page 503
h. Optional: Press Sweep 3 and modify/select items:
— Single
— Continuous OFF ON to ON (default)
—
Restart
— Dwell Time For pulsed RF measurements, it is recommended
that the Dwell Time is increased to ~100 ms.
Default = 10 ms.
—
Max Hold For pulsed RF measurements, it is recommended
that Max Hold is set to OFF when using the Heat Map display.
(Default = OFF)
IMPORTANT! It is not sufficient to be locked to the GNSS satellite, the
frequency reference must be locked to GPS. Refer to
Chapter 31, “System
Settings” and then to “How to make GPS settings” on page 796.