EasyManua.ls Logo

Lenze i950

Lenze i950
500 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
Address Name / seng range / [default seng] Info
0x2878:004 Motor encoder: Encoder monitoring response me
R
ead only: ms
12 12 ms
50 50 ms
100 100 ms
0x287B:001 Velocity monitoring: Tolerance window (n=0)
R
ead only: x rpm
0x2894:001 SS1, SS2: SS1, SS2: Stopping me
R
ead only: x ms
0x2894:002 SS1, SS2: SS1, SS2: Ramp Monitoring
R
ead only
0 No Ramp monitoring
1 Ramp monitoring acve
0x2894:003 SS1, SS2: SS1, SS2: Ramp smoothing me
R
ead only: x %
0x2894:004 SS1, SS2: SS1, SS2: Ramp Oset Mode
R
ead only
0 Relave
1 Absolute
0x2894:005 SS1, SS2: SS1, SS2: Ramp Start Oset relave
R
ead only: x %
0x2894:006 SS1, SS2: SS1, SS2: Ramp Start Oset absolute
R
ead only: x rpm
0x2894:007 SS1, SS2: SS1, SS2: Actual ramp speed
Read only: x rpm
0x2894:008 SS1, SS2: SS1, SS2: Minimal speed diererence
R
ead only: x rpm
0x2899 SS2: Source SD-In
R
ead only
0 Deacvated
1 SD-In1
2 SD-In2
3 SD-In3
4 SD-In4
0x289A SS2: Source S-Bus
Read only
0 Deacvated
1 Acvated
0x289B:001 SS2: SS2: Mode
R
ead only
0 SOS aer stop me
1 SOS at n=0
0x289C SS2 acve: Output
Read only
0 Deacvated
1 SD-Out1 posive logic
2 SD-Out1 negave logic
Safety
funcons
Safe Stop 2 (SS2)
408