Acvaon of the
funcon
A data telegram is sent to the inverter via the safety bus. See chapter "Safe network interfa-
ces". ^ 441
Error behaviour
If the envelope curve is exceeded or when the absolute posion limits are exited, an error
message is triggered and an error stop with the funcon set in the 0x28DE:011 0x28DE:011
parameter is iniated.
Parameter
Address Name / seng range / [default seng] Info
0x28DC PDSS: Source SD-In
•
R
ead only
0 Deacvated
1 SD-In1
2 SD-In2
3 SD-In3
4 SD-In4
0x28DD PDSS: Source S bus
•
Read only
0 Deacvated
1 Acvated
0x28DE:001 PDSS parameters: PDSS: Permanent acvaon
•
R
ead only
0 On demand
1 Acvated
0x28DE:002 PDSS parameters: PDSS: Lower posion limit
•
R
ead only
0x28DE:003 PDSS parameters: PDSS: Upper posion limit
•
Read only
0x28DE:004 PDSS parameters: PDSS: Lower SCS limit
•
Read only
0x28DE:005 PDSS parameters: PDSS: Upper SCS limit
•
Read only
0x28DE:006 PDSS parameters: PDSS: SCS from lower limit
•
Read only: x rpm
0x28DE:007 PDSS parameters: PDSS: SCS from upper limit
•
R
ead only: x rpm
0x28DE:008 PDSS parameters: PDSS: Max. speed
•
Read only: x rpm
0x28DE:009 PDSS parameters: PDSS: Max. delay - lower limit
•
Read only
0x28DE:010 PDSS parameters: PDSS: Max. delay - upper limit
•
Read only
0x28DE:011 PDSS parameters: PDSS: Error response
•
Read only
0 STO
1 SS1
2 SS2
0x28DE:012 PDSS parameters: PDSS: Currently monitored speed
•
Read only: x rpm
0x28DE:013 PDSS parameters: PDSS: Min dierence monitored
speed
•
R
ead only: x rpm
0x28DF PDSS: PDSSpos monitored output
•
Read only
0 Deacvated
1 SD-Out1 posive logic
2 SD-Out1 negave logic
Safety
funcons
Posion-dependent Safe Speed (PDSS)