EasyManua.ls Logo

NEC Xen Master - CLKG-U13 Unit; Figure 5-12 CLKG-U13 Unit

NEC Xen Master
268 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NEC Australia Pty Ltd Xen Master & Xen Axis
5 - 116 Installing Electronic Telephone Units
A6-324000-642-01 – Release 4.0
May 2001
3.4 CLKG-U13 Unit
3.4.1 Description
The CLKG-U13 Unit provides clock synchronisation for
ISDN-BRI and ISDN-PRI lines that are connected to the
system, as well as for the PHS facility. Refer to Figure 5-12
CLKG-U13 Unit.
This unit works in conjunction with the BRT(4)-U13,
PRT(1)-U13 ETU, BSC-U13 ETU or BSU(2)-U13 ETU,
and is plugged onto the CPUB( )-U13 ETU or MBD-U13
Unit.
3.4.2 Installation
Only one CLKG-U13 Unit can be installed in a Xen system.
3.4.3 Connectors
The following connectors are located on the CLKG-U13
ETU.
CN1 Connects to CN5 on the CPUB( )-U13
ETU or MBD-U13 Unit.
CN2 Connects to CN6 on the CPUB( )-U13
ETU or MBD-U13 Unit.
Figure 5-12 CLKG-U13 Unit