NEC Australia Pty Ltd Xen Master & Xen Axis
2 - 24 System Specifications
A6-324000-642-01 – Release 4.0
May 2001
4.3 Power Requirements
4.3.1 Power Supply Inputs
The AC input requirements for the Xen system are listed
below.
AC Input (P64-U13 PSU):
240 Vac +10% / -15%
50 Hz ± 2 Hz
Single Phase
10A circuit
# A dedicated outlet, separately fused and grounded, is
required.
4.3.2 Power Supply Consumption
The power consumption for the Xen system is listed in
Table 2-6 Power Consumption.
4.3.3 Fuse Replacement
When replacing fuses, refer to the specifications in Table
2-7 Fuse Replacement.
Table 2-6 Power Consumption
System KSU
Maximum
RMS
Current
Watts Used
(Idle)
Watts Used
(Maximum)
Xen Master B64-U13 KSU 1.3 A 120 320
B64-U13 KSU +
1 x E64-U13 KSU
2.0 A 240 460
B64-U13 KSU +
2 x E64-U13 KSU
2.9 A 360 690
Xen Axis B48( )-U13 KSU 1.0 A 120 230
Table 2-7 Fuse Replacement
Unit
Fuse
Number
Specifications Description Dimensions
P64-U13 PSU F1 250V, 2.5A AC Input 5 x 20 mm
F101 125V, 10A Battery Input 5 x 20 mm
All fuses are normal blow glass tube.
CAUTION:
Do not use slow blow fuses.
Replace with a fuse of the same type and
rating.