Remote Commands
R&S
®
FSW
1280User Manual 1173.9411.02 ─ 43
ALL
The frequency response correction settings are applied to all
active measurement channels.
Example:
INST:SEL 'MyIQSpectrum'
SENS:CORR:FRES:USER:SCOP CHAN
The filter is applied only to the channel named 'MyIQSpectrum'.
Manual operation: See "Apply to" on page 693
[SENSe:]CORRection:FRESponse<si>:BASeband:USER:SLISt<sli>:CATalog?
[SENSe:]CORRection:FRESponse<si>:INPut<ip>:USER:SLISt<sli>:CATalog?
[SENSe:]CORRection:FRESponse<si>:USER:SLISt<sli>:CATalog?
Returns a list of currently configured touchstone format files.
Suffix:
<si>
.
1..n
irrelevant
<sli> 1..n
Index in Touchstone file list
Use [SENSe:]CORRection:FRESponse<si>:USER:
SLISt<sli>:SIZE? to determine the maximum index number.
Return values:
<arg0> path and file name of all currently configured touchstone format
files.
Example:
SENS:CORR:FRES:USER:SLIS:CAT?
C:\R_S\INSTR\USER\MyS7p.s7p,C:
\R_S\INSTR\USER\MyS2p.s2p
Usage: Query only
[SENSe:]CORRection:FRESponse<si>:BASeband:USER:SLISt<sli>:CLEar
[SENSe:]CORRection:FRESponse<si>:INPut<ip>:USER:SLISt<sli>:CLEar
[SENSe:]CORRection:FRESponse<si>:USER:SLISt<sli>:CLEar
Removes all touchstone files from the current configuration for the selected or all input
types.
Suffix:
<si>
.
1..n
irrelevant
<sli> irrelevant
Example:
SENS:CORR:FRES:USER:SLIS:CLE
Usage: Event
Manual operation: See "Remove File" on page 694