Measurements and Results
R&S
®
FSW
264User Manual 1173.9411.02 ─ 43
Standard files for sub blocks (Multi-SEM measurements)
If more than one sub blocks are defined, the "Standard Files" tab and softkey are not
available. To load a standard file for an individual sub block, use the Standard / MSR
Settings setting in the "Sub Blocks" tab.
Selecting Storage Location - Drive/ Path/ Files...........................................................264
File Name....................................................................................................................264
Load Standard.............................................................................................................264
File Explorer................................................................................................................264
Save Standard............................................................................................................ 265
Delete Standard.......................................................................................................... 265
Restore Standard Files............................................................................................... 265
Selecting Storage Location - Drive/ Path/ Files
Select the storage location of the file on the instrument or an external drive.
The default storage location for the SEM settings files is:
C:\Program Files (x86)\Rohde-Schwarz\FSW\<version>\sem_std.
Note: Saving instrument settings in secure user mode.
In secure user mode, settings that are stored on the instrument are stored to volatile
memory, which is restricted to 256 MB. Thus, a "memory limit reached" error can occur
although the hard disk indicates that storage space is still available.
To store data permanently, select an external storage location such as a USB memory
device.
For details, see Chapter 5.1.7, "Protecting Data Using the Secure User Mode",
on page 43.
Remote command:
MMEMory:CATalog on page 1229
File Name
Contains the name of the data file without the path or extension.
By default, the name of a user file consists of a base name followed by an underscore.
Multiple files with the same base name are extended by three numbers, e.g.
limit_lines_005.
File names must be compatible with the Windows conventions for file names. In partic-
ular, they must not contain special characters such as ":", "*", "?".
For details on the filename and location, see Chapter 11.3.2.2, "Storage Location and
Filename", on page 629.
Load Standard
Loads the selected measurement settings file.
Remote command:
[SENSe:]ESPectrum<sb>:PRESet[:STANdard] on page 918
File Explorer
Opens the Microsoft Windows File Explorer.
Spectrum Emission Mask (SEM) Measurement

Table of Contents