5.System Maintenance
488
However, while the firmware of the operation panel is being updated, cancellation is not possible
because the keys are disabled.
(Since the update of the operation panel firmware is performed at the end, you cannot cancel the
update at this point.)
If the update is canceled, the machine will reboot when the firmware update of all modules included in
the following parts is complete.
1. Engine Board
2. FCU
3. Controller Board (PCB15)
4. Operation Panel
For example, if the first firmware update for the Controller Board (PCB15) is canceled, the machine will
reboot when the firmware update of all modules included in the Controller Board (PCB15) is complete.
The firmware configuration contained in the package is listed in the accompanying SERES release
note.
If the update is canceled, it will be performed again 76 hours later. If there is a difference in version
between the package obtained at that time and the one already stored (in other words, the one
canceled), the old package will be discarded and the latest one will be received.