5.System Maintenance
473
Code
Contents
Solutions
75
The amount of update data has
exceeded the limit. There is too much
data in the removable media.
Move “fwuin the “/romdatadirectory out of
that directory so that the same modules are not
located in the same directory.
83
Package RFU reception has been
canceled by the user.
Package RFU reception has been canceled by
the user.
84
Package RFU reception timeout. The
reception time has exceeded the limit
(100 minutes).
Check the network connection.
Firmware Update (Smart Firmware Update)
Overview
Smart firmware update (SFU) is a system to download a firmware package. Since downloading the
package takes time, SFU lets you schedule the download to take place when the machine is not in use,
such as at night or at the weekend.
There are the following methods of updating using SFU.
1. Immediate Update: To download and update the firmware when visiting.
2. Update on the next visit: To set the date and time for firmware downloading. The firmware will be
automatically downloaded beforehand and updated at the following visit.
"Update on the next visit" is recommended since firmware download may take some minutes due
to the network condition.
SFU requires the connection to @Remote via a device which has the embedded @Remote
communicating function. When a machine is connected to @Remote via an intermediate
device (RC Gate), the SFU function is disabled.
Immediate Update
Enter the [Firmware Update] menu in the SP mode and update the package firmware.
The [Firmware Update] button will appear even when a machine is connected to @Remote
with a device which does not have an embedded @Remote communicating function.
If an error code is displayed, refer to Error Screens During Updating.
1. Enter the SP mode.