6.Troubleshooting
558
SC No.
Type
Error Name/Error Condition/Major Cause/Solution
IOB (PCB17) defective
1. Update the engine software to the latest version.
2. Replace the IOB (PCB17).
SC500 (Engine: Paper Transport 2: Fusing, Others)
SC No.
Type
Error Name/Error Condition/Major Cause/Solution
SC540-
01
D
Fusing Pressure Release Motor (M9) Error 1
The over-current detection signal of the fusing pressure release motor (M9) is
detected 20 times consecutively.
Connector disconnected or defective
Drive transmission of the Fusing pressure release motor (M9) defective
Fusing pressure release motor (M9) defective
Connect-Left PCB (PCB20) defective
IOB (PCB17) defective
Connector disconnected or defective
Reconnect the following connectors. Then perform a conduction inspection. If
there is no conduction, replace the connector.
Fusing Pressure Release Motor (M9) – Connect-Left PCB (PCB20)
connector
Connect-Left PCB (PCB20) – IOB (PCB17) connector
Drive transmission of the Fusing pressure release motor (M9) defective
Check the gears. If any gears are damaged, replace them.
Fusing pressure release motor (M9) defective
Replace the Fusing pressure release motor (M9).
Connect-Left PCB (PCB20) defective
Replace the Connect-Left PCB (PCB20).
IOB (PCB17) defective
Replace the IOB (PCB17).
SC No.
Type
Error Name/Error Condition/Major Cause/Solution
SC540-
02
D
Fusing Pressure Release Motor (M9) Error 2
The position detection sensor is not detected for 30 seconds consecutively after
the fusing pressure release motor (M9) is activated.
Connector defective or disconnected
Drive transmission of the Fusing pressure release motor (M9) defective
Fusing pressure release motor (M9) defective
Connect-Left PCB (PCB20) defective