6.Troubleshooting
562
SC No.
Type
Error Name/Error Condition/Major Cause/Solution
to foreign materials, replace the connectors or the units including the
connectors.
Triac defective
Disconnect the power cord and check that the resistance between terminals
T1 and T2 of the triac TRA31 and triac TRA41 on the PSU (PCB18) are
several Mega-Ohms and not shorted. If failed, replace the PSU (PCB18).
Fusing unit defective
1. Check that no paper jam is present.
2. Reconnect the following connectors.
Fusing Unit – Fusing Thermistor Connection PCB connector
Fusing Thermistor Connection PCB – IOB (PCB17) connector
3. If the connector is broken, shorted, or grounded, replace the connector.
4. Replace the fusing unit.
Fusing thermistor connection PCB defective
Replace the fusing thermistor connection PCB.
IOB (PCB17) defective
1. Update the engine software to the latest version.
2. Replace the IOB (PCB17).
PSU (PCB18) defective
1. Reconnect the following connector.
PSU (PCB18) – IOB (PCB17) connector
2. Replace the PSU (PCB18).
Fusing lamp defective
Replace the fusing unit.
SC No.
Type
Error Name/Error Condition/Major Cause/Solution
SC551-
00
D
Fusing Thermistor (End) Disconnected Error
Input from fusing thermistor (end) (TS1) is 1019 or more (A/D value) continuously
for 4 seconds.
Connector defective or disconnected
Connector pin defective
Triac defective

Table of Contents