6.Troubleshooting
564
SC No.
Type
Error Name/Error Condition/Major Cause/Solution
IOB (PCB17) defective
Connector pin defective
If the I/F connector pins of the fuser unit and the main unit are deformed owing
to foreign materials, replace the connectors or the units including the
connectors.
Triac defective
Disconnect the power cord and check that the resistance between terminals
T1 and T2 of the triac TRA31 and triac TRA41 on the PSU (PCB18) are
several Mega-Ohms and not shorted. If failed, replace the PSU (PCB18).
Fusing thermistor defective
Replace the fusing unit.
IOB (PCB17) defective
Replace the IOB (PCB17).
SC No.
Type
Error Name/Error Condition/Major Cause/Solution
SC581-
00
C
Temperature Sensor Disconnected Error
The average of the output from the temperature sensor is 1019 or more for
160 ms.
The average of the output from the temperature sensor is 930 or more for 5
seconds.
Temperature sensor defective
IOB (PCB17) defective
Temperature sensor defective
1. Reconnect the following connector.
Temperature Sensor – IOB (PCB17) connector
2. If the connector is broken, shorted, or grounded, replace the connector.
3. Replace the temperature sensor.
IOB (PCB17) defective
1. Update the engine software to the latest version.
2. Replace the IOB (PCB17).