R&S
®
CMW 500 GSM Applications
GSM TX Measurements
Operating Manual 1202.3986.32 – 03 211
Power class Nominal maximum output power in dBm
11
12
13
14
15
16
17
18
19 to 28
29
30
31
21
19
17
15
13
11
9
7
5
5
5
5
8
6
4
2
0
0
0
0
0
36
34
32
8
6
4
2
0
0
0
0
0
36
34
32
GSM power control levels
According to the GSM standard, the tolerances for the average burst powers,
measured at various frequencies,depend on the GSM band and PCL; see tables
below. The tolerances are applicable for both normal and access bursts.
The limits can be set in the configuration dialog (for reference information refer to
Average Burst Power Limits).
The tables below list the test requirements of standard 3GPP TS 51.010-1, section
13.3. The following tolerances apply to GSM 400, GSMGT800, GSM 800, and
GSM900 networks: