494
Parameters related to write block list (omissible)
Cannot be used together with parameters related to
NFC(NDEF).
Parameters related to subtraction register (omissible)
rga: Specify the subtraction register A. Set a decimal from 0~4,294,967,295.
The register value for inlet shipping is 4,294,967,295.
Write is possible only when the setting value is below
the value stored in the register.
*1
rgb: Specify the subtraction register B. Set a decimal from 0~4,294,967,295.
The register value for inlet shipping is 4,294,967,295.
Write is possible only when the setting value is below
the value stored in the register.
*1
rgc: Specify the subtraction register C. Set a fixed 16-digit hexadecimal. Specify an even
number for the number of digit.
The hexadecimal for inlet shipping is
FFFFFFFFFFFFFFFF.
This register without subtraction function is regarded
as normal memory.
*1 When writing a value larger than the original data in subtraction register A or B, VERIFY TAG
ERR error will occur.
Parameters related to individualized master key (omissible)
* Specify this parameter to automatically set the individualized card key based on the card key block.
(Set different key for each card)
sdk: Specify the individualized master
key.
Set a fixed 48-digit hexadecimal.
The individualized card key cannot be set if omitted.
Note:
If the individualized master key leaks out, the "individual
key" for all cards can be created easily. As such,
manage and use the individualized master key in a fully
secured environment.
Parameters related to card key version (omissible)
ckv: Specify the card key version. Set a fixed 4-digit hexadecimal.
With sdk: specified and ckv: omitted, the card key
version is written as 0000.
Parameters related to data format code (omissible)
Note:
A parameter error will occur if df1: and df2: are specified together.
df2: can be used only for FeliCa Lite.
df1: Data format
code case 1
Set a fixed 4-digit hexadecimal.
Even if this parameter is specified, the data is written to the ID block
only. The IDm of Polling response is not changed as shown below.
E.g.:

Table of Contents

Other manuals for SATO CL6NX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SATO CL6NX and is the answer not in the manual?

SATO CL6NX Specifications

General IconGeneral
Flash memory2000 MB
Storage mediaFlash
Internal memory256 MB
Built-in barcodesCode 39, Code 93, Code-128 Codabar Library, EAN13, EAN8, GS1 DataBar, Industrial 2/5, Interleaved 2/5, Matrix 2/5
Internal storage capacity2 GB
Cables includedAC
Maximum roll diameter220 mm
Maximum printing width167.5 mm
Printing media thickness0.08 - 0.268 µm
USB portYes
USB connectorUSB Type-A / USB Type-B
Bluetooth version3.0
Serial interface typeRS-232C
USB 2.0 ports quantity2
Connectivity technologyWired & Wireless
Wi-FiNo
Display typeLCD
Product colorBlack
Display diagonal3.5 \
Display resolution320 x 240 pixels
AC input voltage100 - 240 V
AC input frequency50 - 60 Hz
Storage temperature (T-T)-20 - 60 °C
Operating temperature (T-T)0 - 40 °C
Storage relative humidity (H-H)30 - 90 %
Operating relative humidity (H-H)30 - 80 %
TypePOS printer
Print speed10 ips
Print technologyDirect thermal / Thermal transfer
Maximum resolution203 x 203 DPI
Weight and Dimensions IconWeight and Dimensions
Depth457 mm
Width338 mm
Height321 mm
Weight20000 g