Technology instructions
10.3 Motion control
S7-1200 Programmable controller
System Manual, V4.2, 09/2016, A5E02486680-AK
793
Data adaptation errors
ErrorID
ErrorInfo
Description
Remedy
Error reaction
16#8640
Errors when adapting actuator configuration
16#0030 Value has the wrong numerical for-
mat or is outside the valid number
range.
Restart Adaptation Error
16#0059 The device is not assigned to any
SINAMICS drive unit or does not
support the services necessary for
adaptation.
Restart Adaptation Error
16#005A Adaptation was cancelled because of
the lack of resources.
Restart Adaptation Error
16#005B Adaptation is possible only if the
device was wired directly to an IO
area.
Restart Adaptation Error
16#005C Maximum speed (p1082): Parameter
does not exist or its value cannot be
read or is outside the permitted limits.
Reading the parameters was can-
celled because of an error indicated
by the hardware.
Restart Adaptation Error
16#005D Maximum torque/force (p1520): Pa-
rameter does not exist or its value
cannot be read or is outside the per-
mitted limits. Reading the parameters
was cancelled because of an error
indicated by the hardware.
Restart Adaptation Error
16#005E Maximum torque/force (p1521): Pa-
rameter does not exist or its value
cannot be read or is outside the per-
mitted limits. Reading the parameters
was cancelled because of an error
indicated by the hardware.
Restart Adaptation Error
16#005F Fine resolution torque/force limit
(p1544): Parameter does not exist or
its value cannot be read or is outside
the permitted limits. Reading the
parameters was cancelled because
of an error indicated by the hardware.
Restart Adaptation Error
16#0060 Basic speed/rated speed (p2000):
Parameter does not exist or its value
cannot be read or is outside the per-
mitted limits. Reading the parameters
was cancelled because of an error
indicated by the hardware.
Restart Adaptation Error
16#0061 Rated torque/rated force (p2003):
Parameter does not exist or its value
cannot be read or is outside the per-
mitted limits. Reading the parameters
was cancelled because of an error
indicated by the hardware.
Restart Adaptation Error