EasyManua.ls Logo

Spectra T50e - Deleting a Partition

Default Icon
539 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 6—Configuring and Managing Partitions Modifying an Existing Partition
August 2017 User GuideSpectra T50e Library
187
Whenreducingthenumberofslotsassignedtoapartition,physically
exportanycartridgesinthoseslots,asdescribedinExportingor
ExchangingCartridgesonpage207,beforeyouremoveslotsfromthe
partition.
Auto Configuration Save Whenyoumakeachangetoapartition,the
librarygeneratesanautoconfigurationfileandsavesittothememory
cardintheLCM.IfyouconfiguredtheemailoptionfortheAuto
ConfigurationSavefile,anemailcontainingtheupdatedlibrary
configuration,aswellastheMLMandDLMdatabasesandanyBlueScale
encryptionkeysstoredonthelibrary,aresenttothespecifiedrecipient(see
EmailAutoConfigurationSaveonpage109).
Note: Donotusethedefaultautosupport@spectralogic.comemail
recipient.SpectraLogicdoesnotsaveemailedconfigurationfiles
unlesstheyarespecificallyrequestedfortroubleshooting.
Usethefollowingstepstomodifyanexistingpartition.
1. Discontinueanybackupstothepartitionyouwanttomodify.
2. Logintothelibraryasauserwithsuperuseroradministrator
privileges.
3. SelectMaintenance > MLMtodisplaytheMediaLifecycle
ManagementToolsscreen.IfMediaAutoDiscovery,PreScan,or
PostScanisrunning(asindicatedbythepresenceofaStop Discoveryor
Pause PostScanbutton,respectively),dothefollowing:
ClickStop DiscoverytotemporarilystopMediaAutoDiscoveryor
PreScan(seeFigure154onpage245).
ClickPause PostScantopausethePostScanforonehour(see
Figure159onpage254).
4. Ifyouconfiguredthepartitiontouseencryptionorifyouwantto
enableencryptioninapartitionthatdidnotpreviouslyuseit,loginto
theencryptionfeature(see
ConfiguringBlueScaleKeyManagementon
page303).
Important
By default, the library deletes empty slots from a partition first. If all of the slots are
full, the library is forced to delete populated slots. When this happens, the deleted
slots are no longer accessible through the BlueScale interface or the storage
management software. You must add the slots to a new or an existing partition to
access them.

Table of Contents

Other manuals for Spectra T50e

Related product manuals