GE Interfaces Example Output
Software Reference for SwitchBlade x3100 Series Switches (Interface Management)
2-16
SET INTERFACE XE
Syntax
SET INTERFACE={ type: | type:id-range | id-range | ifname-list |
ALL }
XE
[ FLOWCONTROL={ ON | OFF } ]
[ DIRECTION={ NETWORK | CUSTOMER } ]
[ FORCE ]
Description Changes attributes for the specified XE interface
Options The following table gives the range of values for each option that can be specified with
this command and a default value (if applicable).
Example SET INTERFACE ALL FLOWCONTROL ON DIRECTION NETWORK
Option Description Default Value
INTERFACE The XE interfaces that are being modified.
FLOWCON-
TROL
Specifies whether flow control is enabled for GE ports.
For XE4 ports, the parameter can either be ON or
OFF.
If ON, the port can generate and respond to pause sig-
nals with the remote peer.
If OFF, pause is ignored and not generated, and poten-
tial for packet loss is increased.
The user can set this parameter only when the interface
is disabled.
OFF
DIRECTION NETWORK - The interface is toward another system,
and so data packets from multiple customers are carried
over the link.
CUSTOMER - The interface is toward a customer site
and all data streams are associated with the customer.
NETWORK
FORCE Suppress any confirmation message.