6-314
Cisco Unified Communications Manager Managed Services Guide
OL-22523-01
Chapter 6 Cisco Unified Serviceability Alarms and CiscoLog Messages
Notice-Level Alarms
Recommended Action
If the duration of the call is too short, increase the value in the Cisco CallManager service parameter or
disable the maximum duration by setting the Maximum Call Duration Timer parameter to zero. If you
suspect a hung gateway port, check the trace files around the time that this alarm occurred to search for
the gateway that was involved in the call, then check the status of that gateway to determine if all ports
are functioning normally.
SDLLinkISV
SDL link to remote application is restored. This alarm indicates that the local Cisco CallManager has
gained communication with the remote Cisco CallManager.
Note The remote Cisco CallManager should also indicate SDLLinkISV with a different LinkID.
Facility/Sub-Facility
CCM_CALLMANAGER-CALLMANAGER
Cisco Unified Serviceability Alarm Definition Catalog
CallManager/CallManager
Severity
Notice
Parameters
Remote IP address of remote application [String] Unique Link ID. [String] Local node ID [UInt] Local
Application ID. [Enum]RemoteNodeID [UInt] Remote application ID. [Enum]
Enum Definitions for LocalApplicationId and RemoteApplicationID
Recommended Action
None
History
Cisco Unified Communications
Release Action
8.0(1) Severity changed from Informational to Notice.
Code Reason
100 CallManager
200 CTI Manager