OBJECTS { ifStackStatus, ifStackLastChange }
STATUS current
DESCRIPTION
A collection of objects providing information on the layering of MIB-II interfaces.
::= { ifGroups 11 }
ifCounterDiscontinuityGroup OBJECT-GROUP
OBJECTS { ifCounterDiscontinuityTime }
STATUS current
DESCRIPTION
A collection of objects providing information specific to interface counter discontinuities.
::= { ifGroups 13 }
linkUpDownNotificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS { linkUp, linkDown }
STATUS current
DESCRIPTION
The notifications which indicate specific changes in the value of ifOperStatus.
::= { ifGroups 14 }
Deprecated Definitions - Objects
Interface Test Table
This group of objects is optional and deprecated. However, a media-specific MIB may make
implementation of this group mandatory. This table replaces the ifExtnsTestTable.
ifTest Tabl e OBJECT- TYP E
SYNTAX SEQUENCE OF IfTestEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
This table contains one entry per interface. It defines objects which allow a network manager to
instruct an agent to test an interface for various faults. Tests for an interface are defined in the
media-specific MIB for that interface. After invoking a test, the object ifTestResult can be read to
determine the outcome. If an agent cannot perform the test, ifTestResult is set to so indicate. The
object ifTestCode can be used to provide further test-specific or interface-specific (or even
enterprise-specific) information concerning the outcome of the test. Only one test can be in progress
on each interface at any one time. If one test is in progress when another test is invoked, the second
test is rejected. Some agents may reject a test when a prior test is active on another interface.
Before starting a test, a manager-station must first obtain 'ownership' of the entry in the ifTestTable
for the interface to be tested. This is accomplished with the ifTestId and ifTestStatus objects as
follows:
try_again:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco MCS-7825-H3-IPC1 and is the answer not in the manual?

Cisco MCS-7825-H3-IPC1 Specifications

General IconGeneral
BrandCisco
ModelMCS-7825-H3-IPC1
CategorySoftware
LanguageEnglish

Related product manuals