8-78
Cisco Unified Communications Manager Managed Services Guide
OL-22523-01
Chapter 8 Industry-Standard Management Information Base
HOST-RESOURCES-MIB
The index of the hrDeviceEntry for the device from which this host is configured to load its initial
operating system configuration (i.e., which operating system code and/or boot parameters). Note
that writing to this object just changes the configuration that will be used the next time the operating
system is loaded and does not actually cause the reload to occur.
::= { hrSystem 3 }
hrSystemInitialLoadParameters OBJECT-TYPE
SYNTAX InternationalDisplayString (SIZE (0..128))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
This object contains the parameters (e.g. a pathname and parameter) supplied to the load device
when requesting the initial operating system configuration from that device. Note that writing to this
object just changes the configuration that will be used the next time the operating system is loaded
and does not actually cause the reload to occur.
::= { hrSystem 4 }
hrSystemNumUsers OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
The number of user sessions for which this host is storing state information. A session is a collection
of processes requiring a single act of user authentication and possibly subject to collective job
control.
::= { hrSystem 5 }
hrSystemProcesses OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
The number of process contexts currently loaded or running on this system.
::= { hrSystem 6 }
hrSystemMaxProcesses OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
The maximum number of process contexts this system can support. If there is no fixed maximum,
the value should be zero. On systems that have a fixed maximum, this object can help diagnose
failures that occur when this maximum is reached.
::= { hrSystem 7 }