Remote Monitoring
– 413 –
event will not be generated until the sampled value has risen above the falling
threshold, reaches the rising threshold, and again moves back down to the
failing threshold. (Range: 0-2147483647)
◆ Falling Event Index – The index of the event to use if an alarm is triggered by
monitored variables reaching or crossing below the falling threshold. If there is
no corresponding entry in the event control table, then no event will be
generated. (Range: 0-65535)
◆ Owner – Name of the person who created this entry. (Range: 1-127 characters)
Web Interface
To configure an RMON alarm:
1. Click Administration, RMON.
2. Select Configure Global from the Step list.
3. Select Add from the Action list.
4. Click Alarm.
5. Enter an index number, the MIB object to be polled (etherStatsEntry.n.n), the
polling interval, the sample type, the thresholds, and the event to trigger.
6. Click Apply
Figure 266: Configuring an RMON Alarm

Table of Contents

Other manuals for Edge-Core ECS4210-12P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edge-Core ECS4210-12P and is the answer not in the manual?

Edge-Core ECS4210-12P Specifications

General IconGeneral
BrandEdge-Core
ModelECS4210-12P
CategoryNetwork Router
LanguageEnglish

Related product manuals