Chapter 3
| Basic Management Tasks
Setting the System Clock
– 80 –
Web Interface
To manually set the system clock:
1. Click System, then Time.
2. Select Configure General from the Step list.
3. Select Manually from the Maintain Type list.
4. Enter the time and date in the appropriate fields.
5. Click Apply
Figure 12: Manually Setting the System Clock
Setting the SNTP
Polling Interval
Use the System > Time (Configure General - SNTP) page to set the polling interval at
which the switch will query the specified time servers.
Parameters
The following parameters are displayed:
◆ Current Time – Shows the current time set on the switch.
◆ SNTP Polling Interval – Sets the interval between sending requests for a time
update from a time server. (Range: 16-16384 seconds; Default: 16 seconds)
Web Interface
To set the polling interval for SNTP:
1. Click System, then Time.
2. Select Configure General from the Action list.
3. Select SNTP from the Maintain Type list.
4. Modify the polling interval if required.