Using the Equipment
EN/LZT 790 0005 R7A
3-121
RepeatThis flag indicates whether the dynamic L1-post signaling is provided
also for the next frame. This can have the values: Enabled, Disabled.
L1-post constellationThis can have the values: BPSK, QPSK, 16-QAM, 64-
QAM.
L1-post code rate – Always 1/2.
L1-post FEC typeAlways 16K LDPC.
L1-post info sizeThe size of the information part of the L1-post signaling, the
sum of the configurable and dynamic and extension parts, excluding the CRC
and the padding field.
TX idTransmitter ID availability, always set to 0.
Cell id –Uniquely identifies a geographic cell in a DVB-T2 network.
Network idNETWORK_ID extracted from the DVB SI.
System idT2_SYSTEM_ID extracted from the DVB SI.
T2-frame num in a superframe – The number of T2-frames per super-frame.
OFDM symbol num in T2-frameThe number of data OFDM symbols per T2-
frame, excluding P1 and P2.
Regeneration countIndicates how many times the DVB-T2 signal has been
regenerated. Value 0 indicates that no regeneration has been done.
L1-post extensionIndicates the presence of the L1-post extension field. It
can be Present or Not present.
Number of used RF frequenciesIndicates the number of frequencies in the
current T2 system. Always 1, as TFS mode is not supported.
The current RF indexAlways 0, as TFS mode is not supported.
Subslices Per FrameThe total number of sub-slices for the type 2 data PLPs
in one T2-frame.
Num PLSs in a superframeNumber of PLPs in the current superframe.
Always 1, as multi-PLP streams are currently disabled.
Number of auxiliary streams Indicates the number of auxiliary streams.
Note: The following three statuses are only available if Mixed indicator (FEFs
exist) has a value Yes.
FEF typeAll values are reserved for future use.
FEF length in the elementary periodIndicates the length of the associated
FEF part as the number of elementary periods T from the start of the P1 symbol
of the FEF part to the start of the P1 symbol of the next T2-frame.