Alarm Identifiers
EN/LZT 790 0005 R7A
C-7
Name Identifier Description
Frame Sync Out of Sync 1094 Frame Sync is enabled but is not
synchronized with the current video
frame rate or no signal is detected on
the Frame Sync input.
C.2.11 IP Input Alarm Identifiers
Table C.11 IP Input Alarm Identifiers
Name Identifier Description
IPI Ethernet If 1 Down 1100 Link down on port 1
IPI Ethernet If 1 No Data 1101 No data being received on port 1
IPI Ethernet If 1 IP Conflict 1102 Assigned IP address conflicts with
other equipment on network
IPI Ethernet If 2 Down 1103 Link down on port 2
IPI Ethernet If 2 No Data 1104 No data being received on port 2
IPI Ethernet If 2 IP Conflict 1105 Assigned IP address conflicts with
other equipment on network
IPI Ethernet If 1 and 2 Down 1106 Link down on both port 1 and 2
IPI Ethernet If 1 and 2 No Data 1107 Data data is being received on both
port 1 and 2
Port 1 net util 1108 Network utilization is above threshold
Port 2 net util 1109 Network utilization is above threshold
MDI delay factor 1110 The delay factor is greater than set
value
MDI loss rate 1111 The loss rate is above set value
Out of sync 1112 The card has failed to lock to a valid
TS
No response 1113 No response on link
Wrong FEC format 1114 Wrong FEC format
FIFO overflow 1115 FIFO overflowed
Primary interface not in use 1116 If redundancy switch to secondary has
occurred
Primary TS not in use 1117 If redundancy switch to secondary TS
has occurred
All TSs missing at all input IFs 1118 If no multicast is available