Ericsson RX8000 - Setting up SNMP Remote Control

Ericsson RX8000
500 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Using the Equipment
3-28
EN/LZT 790 0005 R7A
3.5 SNMP
Simple Network Management Protocol (SNMP) is available as a standard feature on
all of the RX8000 IRDs.
SNMP is a network protocol used to monitor network-attached devices for conditions
that warrant administrative attention. SNMP consists of a set of standards for
network management, including an application layer protocol, a database schema,
and a set of data objects.
The RX8000 IRDs support SNMP Versions 2C and 3.
3.5.1 Setting Up SNMP Remote Control
SNMP remote control is enabled by default.
To set up SNMP remote control:
1. Ensure the Web Browser Interface is connected and working and switch over to
the Advanced View mode.
2. From the browser SNMP tab, select the version of SNMP required (V2C or V3).
3. Ensure the trap community, read-write community, and read-only community are
configured as public or private in the same way as the MIB browse or SNMP
application being used.
3.5.1.1 SNMP > Parameters
Figure 3.15 SNMP Web Page
Version Enables selection of the SNMP version from a drop-down menu.
Sys Services Enables input of a value for MIB-2 services that this device
primarily offers (MIB-II RFC1213). See MIB-2 for definition.
System Name Enables input of a MIB-2 sys name, which should be an
administratively-assigned name.