Using the Equipment
EN/LZT 790 0005 R7A
3-49
SAT S2X Buffer Overflow (relay mapping) Place a check mark in the box to
activate relay mapping when this alarm is raised.
3.9.3.5 Output Alarms
Figure 3.27 Alarm settings for Output section
Output
IPO Ethernet If 1/2 Down Select the alarm condition from the drop-down
menu to be activated when there is no signal at IPO Ethernet 1/2 (Set Alarm
/No Alarm).
IPO Ethernet If 1/2 Down (relay mapping) Place a check mark in the box to
activate relay mapping for no signal at IPO Ethernet 1/2.
IPO Ethernet If 1 and 2 DownSelect the alarm condition from the drop-down
menu to be activated when there is no signal at IPO Ethernet 1 and 2 (Set Alarm
/No Alarm).
IPO Ethernet If 1 and 2 Down (relay mapping)Place a check mark in the
box to activate relay mapping for no signal at IPO Ethernet 1 and 2.
IPO MGP Failed to go onlineSelect the alarm condition from the drop-down
menu to be activated when there the IP output cannot go online (transmit
multicast data) in an MGP enabled system (Set Alarm /No Alarm).
IPO MGP Failed to go online (relay mapping)Place a check mark in the box
to activate relay mapping for MGP failed to go online.
IPO MGP Potential duplicate txSelect the alarm condition from the drop-
down menu to be activated when there the IP output detects a clashing multicast
on an MGP enabled system (Set Alarm /No Alarm).
IPO MGP Potential duplicate tx (relay mapping) Place a check mark in the
box to activate relay mapping for MGP potential duplicate TS.