Using the Equipment
Figure 3.62 Advanced Status if Receiving a DVB-T2 Stream
• TS Lock in demodulator – `Locked´, `Unlocked´, `Not Detected´.
There are two controls for controlling the power measurement:
• Get power level – Power level is only updated if `Get power level´ is checked,
because measuring the power level will disturb the TS lock.
• Power level measurement unit – `Power level measurement unit´ is the only
control which will not trigger a retune when it is altered. It can have two values:
- dBµV
- dBmW
• Tuner temperature – This displays the tuner temperature in Celsius, it is bound
to a threshold alarm whose threshold can be altered, and the default value is 80.
• LO lock – This displays whether the local oscillator in the tuner is locked.
DVB-T
• Hierarchy – This can have the values: None, α1, α2, α4.
• TPS cell ID – TPS cell ID number (if available, otherwise 0).
DVB-T2
• L1pre type – This is the type of transmitted data. It can be TS, GS, Mixed TS
and GS.
• Mixed indicator (FEFs exist) – No or Yes.