Installing the Equipment
2.3.16 ALARM Connector
All units provide an alarm relay connector supplying a
summary relay. Under user configuration, it is activated
whenever the unit detects an alarm, or the power is
switched off.
The table below shows the pin-out applicable to Software
Version 5.12.0 onwards, or when the Relay Mode is set to
Revised in Software Version 5.16.0 onwards.
Table 2.15 ALARM Connector
Item Specification
Connector type 9-way, D-type, female
Connector designation ALARM
Pin-outs
Pin 1 – Relay 3, Normally Closed
Pin 2 – Relay 2, Common
Pin 3 – Relay 3, Common
Pin 4 – Relay 1, Common
Pin 5 – Relay 3, Normally Open
Pin 6 – Relay 2, Normally Closed
Pin 7 – Relay 2, Normally Open
Pin 8 – Relay 1, Normally Closed (Closed on Alarm)
Pin 9 – Relay 1, Normally Open (Open on Alarm)