Using the Equipment
• MAX PIDS – In this case, the RX8000 has found more components that are
scrambled than are allowed by the configuration of the unit (Maximum CAM
Components). This may not be a problem but does mean that some of the
components scrambled within the service cannot be de-scrambled because of
limitations of the CAM.
3.11.2.9 Front Panel Setup
3.11.2.9.1 CI Module Status
This menu displays the presence of the CI Module (CAM), this will show either
PRESENT or NOT PRESENT, when diagnosing CI issues please check this menu
first, if the CAM has a fault it may not be detected by the unit.
CI |CI MODULE STATUS
5.4.1 |PRESENT
3.11.2.9.2 CI Module Name
This menu displays the name of the CI module (CAM). This is a text string supplied
by the CA vendor and can be any value.
CI |CI MODULE NAME
5.4.2 |VIACCESS
3.11.2.9.3 CI Forced Voltage 3V3
This menu allows the user to override the 3V3 / 5V sense for the CAM. Some CAMs
may be incapable of working correctly with 5V despite being advertised supporting
5V. This control forces the unit to supply only 3.3V to the CAM.
CI |CI VOLTAGE FORCED 3V3
5.4.3 |FALSE
3.11.3 BISS
3.11.3.1 Availability
= Option B = Supplied with Base Model
RX8200
RX8252
RX8305
RX8310
RX8310B
RX8315
RX8320
RX8330
RX8330C
BISS B B B B
BISS/MSD