Using the Equipment
3-170
EN/LZT 790 0005 R7A
Active Boot Bank The S15678 card has 2 banks available to be used for
code download. Code will always download into the inactive bank. This field
shows the current active bank, either 0 or 1.
Alarms This is a general text field which describes any alarms generated by
the card, these alarms are generated by fault conditions found by the NDS
proprietary block of code. These alarms are:
- TS Not Locked
- Smartcard Removed
- Invalid Smartcard
- Smartcard Comms Failure
- Invalid Image
- Invalid Image In Flash
- Number of Elementary Stream > 8
- Invalid PID Configuration
- Processor Overload
- NDS Card Not Accessible
SW Version Describes the software version of the NDS CA Card.
SW Build Time Describes the software build time of the NDS CA Card.
FW Version Describes the firmware version of the NDS CA Card.
CA Verifier Status displays the status provided by the Verifier NDS
proprietary code block, this can have the values:
- OK
- Insert Card
- Invalid Card.
- Service Blocked
- Invalid Packet
- Not Authorized
- Hardware Failure
- Blacked Out
- Invalid Card
- Invalid Pairing