Alarm Identifiers
Name Identifier Description
SAT S2X Upgrade Failed 1412 This alarm is raised when a software
upgrade of the DVB-S2X card has
failed. The alarm can only be reset by
executing a successful software
upgrade.
SAT S2X Not Calibrated 1413 This alarm is raised if there is a
calibration error on the DVB-S2X card.
Optimal performance is not
guaranteed.
SAT S2X Undefined Internal
Error
1414 This alarm is raised when there an
internal error reported by the DVB-S2X
card.
SAT S2X Input Level Too High 1415 This alarm is raised when the DVB-
S2X card experiences an input level
that is too high.
SAT S2X Failed To Acquire
PLL
1416 This alarm is raised when DVB-S2X
card fails to acquire Physical Layer
lock (not applicable for DVB-S).
SAT S2X Failed To Acquire
Lock
1417 This alarm is raised when DVB-S2X
card fails to acquire lock.
SAT S2X DC Overcurrent 1418 This alarm is raised when a DC
overcurrent is detected on the input of
the DVB-S2X card.
SAT S2X Core Overloaded 1419 This alarm is raised when the DVB-
S2X card decoder core is loaded too
high.
SAT S2X Buffer Overflow 1420 This alarm is raised when a buffer
mismatch occurs in the DVB-S2X card.