Using the Equipment
EN/LZT 790 0005 R7A
3-47
Option Card SW Fail (relay mapping) Place a check mark in the box to
activate relay mapping for SW fail.
MER Margin Enter the minimum allowable MER Margin for the DVB-T2
transmission in dB (DVB-T2 card must be fitted). This is used to trigger the
alarm condition, set above, when exceeded.
MER Margin (relay mapping) Place a check mark in the box to activate relay
mapping for MER margin alarm.
Tuner temperature Enter the maximum allowable tuner temperature for the
DVB-T2 card (in degrees) This is used to trigger the alarm condition, set above,
when exceeded.
Tuner temperature (relay mapping) Place a check mark in the box to
activate relay mapping for tuner temperature.
BER Enter the maximum allowable bit error rate for the DVB-T2 card (in dB)
This is used to trigger the alarm condition, set above, when exceeded.
BER (relay mapping) Place a check mark in the box to activate relay mapping
for BER.
SAT S2X Invalid LicenceSelect the alarm condition from the drop-down
menu to be activated if this alarm is raised. This alarm is raised if there is a
licence error reported by the DVB-S2X card.
SAT S2X Invalid Licence (relay mapping)Place a check mark in the box to
activate relay mapping when this alarm is raised.
SAT S2X Self-Test FailSelect the alarm condition from the drop-down menu
to be activated if this alarm is raised. After power-on or reset, the device
performs an internal self-test. If this self-test fails it will trigger this alarm.
SAT S2X Self-Test Fail (relay mapping)Place a check mark in the box to
activate relay mapping when this alarm is raised.
SAT S2X No Input DetectedSelect the alarm condition from the drop-down
menu to be activated if this alarm is raised. This alarm is raised if any one of the
input related alarms on the DVB-S2X card are raised.
SAT S2X No Input Detected (relay mapping)Place a check mark in the box
to activate relay mapping when this alarm is raised.
SAT S2X Over TemperatureSelect the alarm condition from the drop-down
menu to be activated if this alarm is raised. This alarm is raised if the internal
temperature of the DVB-S2X card is outside its operating specification.
SAT S2X Over Temperature (relay mapping)Place a check mark in the box
to activate relay mapping when this alarm is raised.
SAT S2X Upgrade FailedSelect the alarm condition from the drop-down
menu to be activated if this alarm is raised. This alarm is raised when a software
upgrade of the DVB-S2X card has failed. The alarm can only be reset by
executing a successful software upgrade.