22
Configuring MP through an MP-group interface
When you configure MP through an MP-group interface, follow these guidelines:
• The ppp mp max-bind command and the ppp mp min-fragment command you configured
can take effect on an MP bundle only after you re-enable all the physical interfaces in the MP
bundle by executing the shutdown command and then the undo shutdown command.
• After you configure the undo ppp mp fragment enable command on an interface, the settings
configured with the ppp mp lfi and ppp mp min-fragment commands become invalid on the
interface.
To configure MP through an MP-group interface:
Step Command Remarks
1. Enter system view.
system-view
N/A
2. Create an MP-group
interface and enter its view.
interface mp-group
mp-number N/A
3. Set the maximum number of
links in an MP bundle.
ppp mp
max-bind
max-bind-num
Optional.
The default setting is 16.
4. Configure the MP sort buffer
size factor.
ppp mp sort-buffer-size
size
Optional.
The default setting is 1.
5. Enable MP fragmentation.
ppp mp fragment enable
Optional.
By default, MP fragmentation is
disabled.
6. Set the minimum size of MP
fragments.
ppp mp
min-fragment
size
Optional.
The default setting is 128 bytes.
7. Set the interface description.
description
text
Optional.
By default, the description of an
MP-group interface is interface
name Interface.
8. Set the MTU size of the
interface.
mtu
size
1500 bytes by default.
9. Set the intended bandwidth
for the MP-group interface.
bandwidth
bandwidth-value
Optional.
10. Restore the default settings
for the MP-group interface.
default
Optional.
11. Bring up the interface.
undo shutdown
Optional.
By default, the interface is up.
12. Return to system view.
quit
N/A
13. Enter interface view.
interface
interface-type
interface-number
N/A
14. Configure software support
for MP binding.
ppp mp soft-binding
By default, MP binding is
supported in hardware.
Software support for MP binding
can only be configured on CPOS
interfaces.
15. Add the interface to the
MP-group and configure it to
operate in MP mode.
ppp mp mp-group
mp-number N/A

Table of Contents

Other manuals for HPE FlexNetwork MSR Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexNetwork MSR Series and is the answer not in the manual?

HPE FlexNetwork MSR Series Specifications

General IconGeneral
BrandHPE
ModelFlexNetwork MSR Series
CategoryNetwork Router
LanguageEnglish

Related product manuals