Parameter
Address Name / seng range / [default seng] Info
0x2C04:001 Inductance grid points (y) Lss saturaon characteris-
c: y1 = L01 (x = 0.00 %)
0 ... [165] ... 400
%
Saturaon characterisc of the leakage inductance.
The linear distribuon via the current results from the maximum motor
current (0x2C05).
0x2C04:002 Inductance grid points (y) Lss saturaon characteris-
c: y2 = L02 (x = 6.25 %)
0 ... [200] ... 400 %
0x2C04:003 Inductance grid points (y) Lss saturaon characteris-
c: y3 = L03 (x = 12.50 %)
0 ... [146] ... 400
%
0x2C04:004 Inductance grid points (y) Lss saturaon characteris-
c: y4 = L04 (x = 18.75 %)
0 ... [117] ... 400
%
0x2C04:005 Inductance grid points (y) Lss saturaon characteris-
c: y5 = L05 (x = 25.00 %)
0 ... [97] ... 400 %
0x2C04:006 Inductance grid points (y) Lss saturaon characteris-
c: y6 = L06 (x = 31.25 %)
0 ... [82] ... 400 %
0x2C04:007 Inductance grid points (y) Lss saturaon characteris-
c: y7 = L07 (x = 37.50 %)
0 ... [71] ... 400 %
0x2C04:008 Inductance grid points (y) Lss saturaon characteris-
c: y8 = L08 (x = 42.75 %)
0 ... [62] ... 400 %
0x2C04:009 Inductance grid points (y) Lss saturaon characteris-
c: y9 = L09 (x = 50.00 %)
0 ... [55] ... 400 %
0x2C04:010 Inductance grid points (y) Lss saturaon characteris-
c: y10 = L10 (x = 56.25 %)
0 ... [50] ... 400 %
0x2C04:011 Inductance grid points (y) Lss saturaon characteris-
c: y11 = L11 (x = 62.50 %)
0 ... [46] ... 400 %
0x2C04:012 Inductance grid points (y) Lss saturaon characteris-
c: y12 = L12 (x = 68.75 %)
0 ... [43] ... 400 %
0x2C04:013 Inductance grid points (y) Lss saturaon characteris-
c: y13 = L13 (x = 75.00 %)
0 ... [42] ... 400 %
0x2C04:014 Inductance grid points (y) Lss saturaon characteris-
c: y14 = L14 (x = 81.25 %)
0 ... [41] ... 400 %
0x2C04:015 Inductance grid points (y) Lss saturaon characteris-
c: y15 = L15 (x = 87.50 %)
0 ... [41] ... 400 %
0x2C04:016 Inductance grid points (y) Lss saturaon characteris-
c: y16 = L16 (x = 93.25 %)
0 ... [41] ... 400 %
0x2C04:017 Inductance grid points (y) Lss saturaon characteris-
c: y17 = L17 (x = 100.00 %)
0 ... [41] ... 400 %
0x2C04:018 Inductance grid points (y) Lss saturaon characteris-
c:
Acvaon Lss saturaon characterisc
Switch on/o the correcon by means of saturaon characterisc.
0 Adjustment o
1 Adjustment on
0x2C05 Reference for current grid points (x) Lss saturaon
characterisc
0.0 ... [5.4] ... 500.0
A
Seng of the maximum motor current.
Serves as reference value for the scaled current data of the X axis of the
saturaon characterisc.
Conguring the motor control
Fine adjus
tment of the motor model
Correcon of the stator leakage inductance (Lss)...