on the primary NLI to each QLPS side. However, of those 256
timeslots, 16 timeslots are reserved, leaving 240 available timeslots.
Refer to Table 4-9, “Control - messaging timeslots” (4-12) for
additional information.
Table 4-9 Control - messaging timeslots
Primary NLI timeslots available for
control/messaging
256
Reserved timeslots 16
Timeslots required per GQPH 24
Timeslots required per QPH 12
Table 4-10, “GQPH Equipage” (4-12) provides the GQPH hardware
required to support the maximum message load for IP trunking, based
on the office configuration. One TN113 is recommended as a spare
for each GQPH equipped shelf.
Table 4-10 GQPH Equipage
Required Hardware Configuration
IOST IOSE
PH33 (TN113) Packs 2 2
General QLPS Protocol Handler (GQPH)
Considerations
Engineering Considerations
....................................................................................................................................................................................................................................
4-12
Lucent Technologies 235-200-118
Issue 3.02B, March 2007