Initiate SCTP Heartbeat
....................................................................................................................................................................................................................................
Purpose
This procedure requests that a manual SCTP heartbeat test be
executed to evaluate the SCTP association path for
• each association in an association set,
• each association in an association set that serves the packet
group,
• a specific association number or
• a specific destination address
When to use
According to local practices for routine maintenance, use this
procedure for verifying connectivity of an SCTP association path or
the transport layer to the far end.
Related information
Refer to the Input Messages Manual, 235-600-700, and the Output
Messages Manual, 235-600-750, for additional information.
Admonishments
None.
Before you begin
Required Tools
• Use of Master Control center (MCC) or Supplementary Trunk
Line Workstation (STLWS).
Required Material
• The switch must be running a 5E16.2 FR3 software release or
later with the SIP for Packet Trunking feature software.
Required Information
• Office Record 5889 for Association Data.
• Office Record 5890 for Association Set Data.
• Office Record 5219 for Packet Group Data.
• Destination IP address.
Required Conditions
• None required.
Procedure
............................................................................................................................................................
1
Initiate a manual heartbeat test on a specific association set name:
Maintenance Considerations
....................................................................................................................................................................................................................................
7-18
Lucent Technologies 235-200-118