Provision Alarm Level for IP Fragmented Packets Beyond PM
Threshold
....................................................................................................................................................................................................................................
Purpose
The IP Fragmented Packets alarm alerts the switch personnel of a
potential security problem. The Threshold Alarm Level view (RC/V
8.29) is used to enable or disable the alarm.
When to use
This procedure is executed to enable the IP Fragmented Packets
Alarm. By default the alarm is disabled.
Related information
Refer to 235-118-258, Recent Change Reference for information on
the RC/V system.
Admonishments
Disabling the alarm could cause a security problem to go unnoticed
by the switch personnel.
Before you begin
Required Tools
• Supplemental Trunk Line Workstation (STLWS) or Recent
Change and Verify (RC/V) terminal
• Access to RC/V Menu Interface
Required Material
• The 5ESS
®
switch must be running a 5E16.2 FR3 software
release or later with the SIP for Packet Trunking - NAR feature
software.
Required Information
• None.
Required Conditions
• None.
Procedure
............................................................................................................................................................
1
Select and prepare terminal for RC/V activities.
Reference:
“Select and Prepare Terminal” (5-11)
............................................................................................................................................................
2
Type and enter the RC/V form number.
8.29
Provisioning
....................................................................................................................................................................................................................................
5-150
Lucent Technologies 235-200-118
Issue 3.02B, March 2007