Change SCTP Endpoint Parameters
....................................................................................................................................................................................................................................
Purpose
SCTP Endpoint Parameters (RC/V 33.18) view is used to update the
SCTP endpoint related timers and protocol parameters.
When to use
Use this procedure to update the SCTP endpoint parameters.
Related information
Refer to 235-118-258, Recent Change Reference, for information on
the RC/V system.
Admonishments
None.
Before you begin
Required Tools
• Supplemental Trunk Line Workstation (STLWS) or Recent
Change and Verify (RC/V) terminal
• Access to RC/V Menu Interface
Required Material
• The 5ESS
®
switch must be running a 5E16.2 FR3 software
release or later with the SIP for Packet Trunking - NAR feature
software.
Required Information
• SCTP Endpoint parameter set name
Required Conditions
• None
Procedure
............................................................................................................................................................
1
Select and prepare terminal for RC/V activities.
Reference:
“Select and Prepare Terminal” (5-11)
............................................................................................................................................................
2
Type and enter the RC/V form number.
33.18
Result:
Enter Database Operation I=Insert,R=Review,U=Update,
D=Delete:
Provisioning
....................................................................................................................................................................................................................................
5-142
Lucent Technologies 235-200-118