EasyManua.ls Logo

Lucent Technologies 5ESS - Delete All SIP GQPH Pipes (RC;V 17.24)

Lucent Technologies 5ESS
552 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Delete All SIP GQPH Pipes (RC/V 17.24)
....................................................................................................................................................................................................................................
Purpose
The QPH Pipe Assignment (RC/V 17.24) defines the GQPH pipe
connecting the QPH or GQPH to the QLPS network.
When to use
Use this procedure to deprovision all GQPH pipes for SIPT service.
NOTE: This is not needed for a DRM/VCDX environment.
Related information
Refer to 235-118-258, Recent Change Reference for information on
the RC/V system.
Refer to 235-080-100, Translations Guide, for information on Office
Records (output reports).
Refer to the 235-600-700/750, Input/Output Messages manuals for
additional information on the Input and Output commands.
Admonishments
The GQPH’s will revert to STBY mode on MCC page 118X,Y,X.
Before you begin
Required Tools
Supplemental Trunk Line Workstation (STLWS) or Recent
Change and Verify (RC/V) terminal
Access to RC/V Menu Interface
Required Material
The 5ESS
®
switch must be running a 5E16.2 FR3 software
release or later with the SIP for Packet Trunking - NAR feature
software.
Required Information
GSM number
PSU Shelf
Channel Group
QLPS Network
Required Conditions
All connectivity for SIP-T service to NGSMs has been deleted on
RC/V 17.27
Deprovisioning
....................................................................................................................................................................................................................................
6-72
Lucent Technologies 235-200-118
Issue 3.02B, March 2007

Table of Contents

Related product manuals